中文 English Pусский Espa?ol

ZVF380 Frequency Converter

ZVF380 Frequency Converter
ZVF380 Frequency Converter
ZVF380 Frequency Converter
ZVF380 Frequency Converter
ZVF380 Frequency Converter
ZVF380 Frequency Converter
ZVF380 Frequency Converter

Main Features

1.Advanced vector control algorithm, adaptive to parameter changes caused by motor changes, improve the tolerance of system control.

2.No PG vector control (SVC), PG vector control (VC), V/F control, torque control and other control methods  can be selected .

3.Auto tuning of static and dynamic motor parameters can be realized, so that the inverter can be automatically adjusted to the best operating state.

4.NPN and PNP two modes of multi-function input terminals, can provide compatible switch signal with any external equipment.

5.Built-in PLC function, which can realize operation modes such as stopping after a single cycle, maintaining the final value after a single cycle, and continuous cycle ect.

6.Rich combination of frequency sources, more flexible to use.

7.Special functions such as swing frequency, fixed length and counting can be realized.

8.Realize the delay function of programmable relay and open collector output.

9.Droop control function realizes automatic load balance.

10.High-speed pulse input and output function.

11.Built-in PID function to realize closed-loop control of flow, temperature and pressure.

12.Standard MODBUS communication protocol, easy to realize the communication with PLC, industrial computer and other industrial control equipment.

13.Multiple password protection to protect user rights.

14.Compact structure, independent air duct design, greatly improve power density, and effectively reduce user installation volume requirements.

15.Wide grid voltage design, especially suitable for domestic low-voltage special occasions. 

16.Wide industry applications, special function modules can be expanded according to different industries.

 

Demonstration of the Model

Inverter Outline & Mounting Dimension (Unit:mm)

 

 

 

Inverter Model   Power (KW)     Current  (A)   Dimension (mm)   Figure  
     H           H1           W           W1           D           d     
   ZVF380-G0R4S2MD    0.4 2.3 186 172 125 113 180 5 Fig.1
ZVF380-G0R7S2MD 0.75 4 186 172 125 113 180 5
ZVF380-G1R5S2MD 1.5 7.0  186 172 125 113 180 5
ZVF380-G2R2S2MD 2.2 9.6 186 172 125 113 180 5
ZVF380-G3R7S2MD 3.7 17 249 236 160 147 197 5
ZVF380-G5R5T2MD 5.5 25 322 304 208 194 204 6
ZVF380-G7R5T2MD 7.5 32 322 304 208 194 204 6
ZVF380-G0R7T4MD 0.75 2.1 186 172 125 113 180 5
ZVF380-G1R5T4MD 1.5 3.8 186 172 125 113 180 5
ZVF380-G2R2T4MD 2.2 5.1  186 172 125 113 180 5
ZVF380-G3R0T4MD 3.0  6.8  186 172 125 113 180 5
ZVF380-G4R0T4MD 4.0  9.0  249 236 160 147 197 5
ZVF380-G5R5T4MD 5.5 13 249 236 160 147 197 5
ZVF380-G7R5T4MD 7.5 17 249 236 160 147 197 5
ZVF380-G011T4MD 11 25 322 304 208 194 204 6
ZVF380-G015T4MD 15 32 322 304 208 194 204 6

 

Description of technical indications

 

Item Item Description
Input Rated Voltage&Frequency Single/Three phase 200-240VAC, Three phase 360-440VAC,50/60Hz
Allowable voltage range Voltage fluctuate range: ±10%
Voltage unbalance rate: <3%
Frequency fluctuation:≤±5%
Output Rated voltage Three phase 0~Input AC voltage
Frequency 0.00~500.00Hz
Overload capacity Type G:150% 1minute,180% 3 second, 200% Instant protection
Type P:120% 1minute,150% 3 second, 180% Instant protection
Control function Modulation Optimize space voltage vector PWM modulation
Control method Closed loop control (FVC), open loop control (SVC), V/F control
Frequency resolution Digital setting:0.01Hz; Analog setting: Max. frequency×0.1%
Starting torque Type G:0.5Hz/150%(SVC); 0Hz/180%(FVC)
Type P:0.5Hz/100%
Speed range 1:100 (SVC) 1:1000 (FVC)
Steady velocity precision ±0.5%(SVC) ±0.02%(FVC)
Torque control precision ±5%(FVC)
Torque boost Automatic torque boost,automatically boost torque according to output current.
Manual torque boost, range:0.1~30.0%
V/F curve 3 ways:linear  curve; Multi-point Curve; Nth power  V/F curve.
(1.2th power,1.4th power,1.6th power,1.8th power,2th power)
V/F separation 2ways:full separation, half separation
Acceleration and deceleration curve Linear or S-curve acceleration/deceleration mode.
4 acceleration and deceleration time, the range of
acceleration and deceleration time is 0.0~6500.0s. 
Carrier frequency 1.0~15.0KHz
Jog function Jog frequency range: 0.01~50.00Hz, jog acceleration and deceleration time
0.1~6500.0 can be set.
Simple PLC
multi-speed operation
Realize up to 16-speed operation through built-in PLC or control terminal.
Automatic voltage regulator(AVR) When the grid voltage changes, it can automatically adjust the PWM output to keep the output voltage constant.
Built-in PID Conveniently form a closed-loop control system, suitable for process control such as pressure control and flow control.
Over-voltage over current stall control Automatically limit the current and voltage during operation to prevent
frequent over-current and over-voltage trips.
Rapid current limit function Minimize over-current faults and protect the inverter from normal operation.
Torque limit and control The "shovel" feature automatically limits the torque during operation to prevent frequent over-current trips; closed-loop vector mode can realize torque control.
Special feature Outstanding performance Realize asynchronous motor control with high-performance current vector control technology.
Power dip ride through When instantaneous power failure occurs, the load feedback energy is used to compensate for the voltage drop, and maintain the inverter to continue running for a
 short time.
Rapid current limit Avoid frequent over-current faults of the inverter.
VirtualI/O 5 groups of virtual DIDO, can realize simple logic control.
Timing control Timing control function: set time range 0.0Min ~ 6500.0Min.
Multi-motor switchover Two motors can be switched over via two groups of motor parameters.
Multithreaded bus support Support 4  field buses: Modbus, Profibus-DP, CANlink, CANopen .
Multi-encoder support Support differential, open collector, UVW, resolver, sine and cosine encoders.
Operation function Operation instruction Operation panel control, external terminal control, serial communication control.
Can be switched in a variety of ways.
Frequency setting 10 kinds of frequency sources: digital setting, analog voltage setting, analog current setting.
Pulse setting, serial port setting.
Can be switched in a variety of ways.
Auxiliary frequency source 10 kinds of auxiliary frequency sources. Flexible realization of auxiliary frequency fine-tuning and frequency synthesis.
Input terminal Standard:
6digital input terminals, one of which supports high-speed pulse input up to 100kHz.
2 analog input  terminals, 1 only supports 0~10V voltage input.
1 supports 0 ~ 10V voltage input or 0 ~ 20mA current input.
Expansion capacity:
5 digital input terminals.
1 analog input terminal, support -10V ~ 10V voltage input, and support PT100/PT1000.
Output terminal Standard:
1 high-speed pulse output terminal (open collector type is optional).
Support 0~100kHz square wave signal output.
1 digital output terminal, 1 relay output terminal.
2 analog output terminals, support 0~20mA current output or 0~10V voltage output.
Expansion capacity:
1 digital output terminal, 1 relay output terminal.
1 analog output terminal, support 0~20mA current output or 0~10V voltage output..
Braking function Dynamic braking External braking resistor, maximum braking torque 100%.
DC braking It can be selected separately when starting and stopping, the action frequency is 0~600Hz, the action current level is 0~150%, the action time is 0~50 seconds, continuous can be set.
LED display Real-time display of the inverter's operating status, monitoring parameters, function parameters, fault codes and other information.
Other functions Jump frequency, counter, speed tracking, restart after instantaneous power failure, upper and lower limit of frequency, adjustable acceleration and deceleration mode, two-wire/three-wire control, swing frequency control, automatic fault reset, frequency arrival output, cooling fan control, multi-function buttons Custom settings, etc.
Protection function Power-on motor short-circuit detection, input and output phase loss protection, over current protection, overvoltage protection, under voltage protection, overheat protection, overload protection, etc.
Optional accessories Braking component, remote operation panel and connecting cable , communication board.
Environment Place to be used Indoors, free from direct sunlight, free of dust, corrosive gas, flammable and explosive gas, oil mist, water vapor, dripping water or salt.
Altitude Less than 1000 meters.
Ambient temperature -10~+45℃[The bare is:-10~+50℃]
Humidity 20~90%RH,No condensation.
Vibration <0.5G
Storage temperature -20~+60℃
Structure Protection level IP20
Cooling method Forced air cooling
Installation method Wall-mounted, floor-standing electric control cabinet.

News Center

> What is a Frequency Inverter?

A frequency inverter is designed to manage the operation of electric motors by adjusting the frequency of the input power. By controlling the speed and torque of the...

Release Date:2024-09-02

> What is a Solar Pumping Inverter

A Solar Pumping Inverter is a device designed to convert the direct current (DC) electricity generated by solar panels into alternating current (AC) to power water p...

Release Date:2024-08-27

> How to operate the motor control panel?

As the core component of the motor control system, the correct operation of the motor control panel is crucial to ensure the stable operation of the motor, improve p...

Release Date:2024-07-30

> how does a soft start work?

It is a device used to control the starting process of an AC motor. Its main purpose is to limit the initial large current inrush of the motor at startup, thereby pr...

Release Date:2024-06-26

GET A QUOTE

Get in Touch
×
We value your privacy
We use cookies to provide you with a better online experience, analyse and measure website usage, and assist in our marketing efforts.
Accept All
芦溪县| 从江县| 湖南省| 宜兰市| 施甸县| 宁晋县| 加查县| 陵水| 西昌市| 北安市| 贺州市| 凌源市| 内黄县| 龙海市| 涡阳县| 林甸县| 柳州市| 松桃| 安远县| 广水市| 怀集县| 临朐县| 剑阁县| 青州市| 灵璧县| 西乌| 景德镇市| 潢川县| 万载县| 大宁县| 巴马| 峨边| 扬中市| 平和县| 佛山市| 博客| 永善县| 邯郸市| 巢湖市| 云南省| 宝兴县|