Product introduction
The wirewound resistor is made by fixing two leading-out terminals on the cylindrical ceramic tube which is coiled by bandlet and wave shape alloy resistance wire. The surface of the ceramic tube is coated by layer of coating which is resistant to flaming and high temperature. As the framework of the resistance wire. The ceramic tube can also work as the radiator .this product can be made to order .It is suitable for simulated load test .the discharging of equipment .automatic control and the dynamic braking of the transducer.
Two terminal extensions are fixed on both ends of a ceramic tube on whose surface winds wave-shaped alloy resistance wire and a high temperature-resistant and fireproof coating are applied. The ceramic tube can function as resistance wire skeleton and heat radiator as well . This product can be customized to special needs of customers and applicable to simulation load test, equipped discharge, automated control and inverter’s energy loss brake.
Technical Data:
Rated Power Range: 50W-2500W
Voltage Range: 0.5KV—10KV
Resistance Range: 1R-1KR
Dielectric Voltage: AC2.5KV-20KV/1min 50Hz
IP Class: IP00
Vibration: 1g
Rated Temperature Rise: 375℃
Temperature Coefficient: 80-400ppm/℃
Carrier Material: 0Cr25AL5/Ni80Cr20 Optional
Advantage: Work in high voltage
Disadvantage: Inferior vibration
Packing: Paper box
Outline& Mounting Dimension (Unit:mm)
Rated power (w) |
Dimension(mm) |
||||||||||
L1(±2) |
L2(±5) |
L3(±3) |
D(±2) |
B |
B1 |
H |
H1(±3) |
N |
¢d |
O |
|
50 |
102 |
124 |
146 |
28 |
6.5 |
28 |
28 |
61 |
10 |
4.5 |
1.2 |
60 |
102 |
124 |
146 |
28 |
6.5 |
28 |
28 |
61 |
10 |
4.5 |
1.2 |
80 |
152 |
174 |
196 |
28 |
6.5 |
28 |
28 |
61 |
10 |
4.5 |
1.2 |
100 |
182 |
204 |
226 |
28 |
6.5 |
28 |
28 |
61 |
10 |
4.5 |
1.2 |
120 |
182 |
204 |
226 |
28 |
6.5 |
28 |
28 |
61 |
10 |
4.5 |
1.2 |
150 |
195 |
217 |
239 |
40 |
8 |
40 |
41 |
81 |
12 |
5.5 |
2.0 |
200 |
195 |
217 |
239 |
40 |
8 |
40 |
41 |
81 |
12 |
5.5 |
2.0 |
300 |
282 |
304 |
326 |
40 |
8 |
40 |
41 |
81 |
12 |
5.5 |
2.0 |
400 |
282 |
304 |
326 |
40 |
8 |
40 |
41 |
81 |
12 |
5.5 |
2.0 |
500 |
316 |
338 |
360 |
50 |
8 |
50 |
45 |
101 |
16 |
6 |
2.0 |
600 |
345 |
367 |
389 |
40 |
8 |
40 |
41 |
81 |
12 |
5.5 |
2.0 |
750 |
316 |
338 |
360 |
50 |
8 |
50 |
45 |
101 |
16 |
6 |
2.0 |
1000 |
300 |
325 |
350 |
60 |
8.5 |
60 |
60 |
119 |
16 |
6 |
2.0 |
1200 |
415 |
440 |
465 |
60 |
8.5 |
60 |
60 |
119 |
16 |
6 |
2.0 |
1500 |
415 |
440 |
465 |
60 |
8.5 |
60 |
60 |
119 |
16 |
6 |
2.0 |
2000 |
510 |
535 |
560 |
60 |
8.5 |
60 |
60 |
119 |
16 |
6 |
2.0 |
2500 |
600 |
625 |
650 |
60 |
8.5 |
60 |
60 |
119 |
16 |
6 |
2.0 |
Note:For bigger power inverter ,we suggest you use braking resistor box.
Wiring Diagram for Inverter System
Recommended brake assembly matching specification
Inverter | Braking Unit | Braking resistor | ||||
Voltage(V) | Motor(KW) | Model | Quantity(PCS) | Recommed resistor value | Resisitor specification | Quantity(PCS) |
220V | 0.75KW | Built-in | 80W200Ω | 80W200Ω | 1 | |
1.5KW | Built-in | 200W100Ω | 200W100Ω | 1 | ||
2.2KW | Built-in | 300W70Ω | 300W70Ω | 1 | ||
3.7KW | Built-in | 400W40Ω | 400W40Ω | 1 | ||
380V | 0.75KW | Built-in | 80W750Ω | 80W750Ω | 1 | |
1.5KW | Built-in | 200W400Ω | 200W400Ω | 1 | ||
2.2KW | Built-in | 300W250Ω | 300W250Ω | 1 | ||
3.7KW | Built-in | 400W150Ω | 400W150Ω | 1 | ||
5.5KW | Built-in | 600W100Ω | 600W100Ω | 1 | ||
7.5KW | Built-in | 800W75Ω | 800W75Ω | 1 | ||
11KW | Built-in | 1000W50Ω | 1000W50Ω | 1 | ||
15KW | Built-in | 1500W40Ω | 1500W40Ω | 1 | ||
18.5KW | 4030 | 1 | 2500W35Ω | 2500W35Ω | 1 | |
22KW | 4030 | 1 | 3000W27.2Ω | 3000W27.2Ω | 1 | |
30KW | 4030 | 1 | 5000W19.2Ω | 2500W38.4Ω | 2 | |
37KW | 4045 | 1 | 6000W16Ω | 2000W48Ω | 3 | |
45KW | 4045 | 2 | 9600W13.6Ω | 2500W54.4Ω | 4 | |
55KW | 4030 | 2 | 12000W10Ω | 2000W60Ω | 6 | |
75KW | 4045 | 2 | 19200W6.8Ω | 2500W54.4Ω | 8 | |
Braking Resistor Box | Quantity(PCS) | |||||
90KW | 4030 | 3 | 9600W20Ω | 3 | ||
100KW | 4220 | 1 | 9600W20Ω | 3 | ||
132-160KW | 4220 | 1 | 40KW3.4Ω | 1 | ||
185-220KW | 4220 | 1 | 60KW3.2Ω | 1 | ||
250-315KW | 4220 | 2 | 40KW4.5Ω | 2 | ||
315-600KW | 4220 | 3 | 60KW3Ω | 3 |
Related Products
News Center
> What is a Frequency Inverter?
A frequency inverter is designed to manage the operation of electric motors by adjusting the frequency of the input power. By controlling the speed and torque of the...
> What is a Solar Pumping Inverter
A Solar Pumping Inverter is a device designed to convert the direct current (DC) electricity generated by solar panels into alternating current (AC) to power water p...
> How to operate the motor control panel?
As the core component of the motor control system, the correct operation of the motor control panel is crucial to ensure the stable operation of the motor, improve p...
> how does a soft start work?
It is a device used to control the starting process of an AC motor. Its main purpose is to limit the initial large current inrush of the motor at startup, thereby pr...