Product features
The BRU series of products are resistor boxes that are assembled with wire wound resistors and are applicable for power-consuming circuits of inverter for braking equipment with large rated power and current ,testing equipment ,elevator and crane .its operating voltage is 500V DC and rated power ranges from 1KW to 10KW.
Technical Indications
- Power Range:2.4W-20KW
- Operating Voltage Range:<800V
- Resistance Range:1R-1KR
- Electric strength: AC 3KV 50HZ 5S
- IP Grade:IP20/IP23
- Vibration:0.5g
- Range of temperature excursion: <400ppm/℃
- Material of the current carrier: 0Cr25AL5.
- Advantages: relatively bad working environment.
Outline& Mounting Dimension (Unit: mm)
Type |
Power(kW) |
Dimension(mm) |
Terminal |
Weight(kg) |
Cable(m㎡) |
Combination |
|||||
W±3 |
D±3 |
H±3 |
H1±4 |
D1±4 |
W1±4 |
||||||
BRU |
2.4 |
251 |
500 |
117 |
147 |
480 |
180 |
M6 |
7.3 |
6 |
600W*4 |
3.0 |
281 |
500 |
132 |
161 |
480 |
240 |
M6 |
9.5 |
6 |
0.5KW*3 |
|
4.5 |
341 |
600 |
142 |
172 |
560 |
291 |
M6 |
12.5 |
10 |
1.5kW*4 |
|
4.8 |
341 |
600 |
142 |
172 |
560 |
291 |
M6 |
12.5 |
10 |
1.5KW*4 |
|
6.0 |
341 |
600 |
142 |
172 |
560 |
291 |
M6 |
12.5 |
10 |
1.5KW*4 |
|
8 |
410.5 |
685 |
145 |
172 |
642 |
340 |
M6 |
15.4 |
16 |
2.0KW*4 |
|
10 |
410.5 |
685 |
145 |
172 |
642 |
340 |
M6 |
17.2 |
16 |
2.0KW*5 |
|
16 |
410.5 |
685 |
142 |
344 |
642 |
340 |
M6 |
30.8 |
16 |
8KW*2 |
|
20 |
410.5 |
685 |
142 |
344 |
642 |
340 |
M6 |
34.4 |
16 |
10KW*2 |
Wiring Diagram for Inverter System
Inverter |
Breaking Unit |
Breaking Resistor |
||||
Voltage |
Motor ( kW ) |
Model |
QTY(PCS) |
Recommended Resistance Value |
Resistor specification |
Qty (PCS) |
220V |
0.75kW |
Built-in |
|
80W200Ω |
80W200Ω |
1 |
1.5 kW |
Built-in |
|
200W100Ω |
200W100Ω |
1 |
|
2.2 kW |
Built-in |
|
300W70Ω |
300W70Ω |
1 |
|
3.7 kW |
Built-in |
|
400W40Ω |
400W40Ω |
1 |
|
380V |
0.75kW |
Built-in |
|
80W750Ω |
80W750Ω |
1 |
1.5 kW |
Built-in |
|
200W400Ω |
200W400Ω |
1 |
|
2.2 kW |
Built-in |
|
300W250Ω |
300W250Ω |
1 |
|
3.7 kW |
Built-in |
|
400W150Ω |
400W150Ω |
1 |
|
5.5 kW |
Built-in |
|
600W100Ω |
600W100Ω |
1 |
|
7.5 kW |
Built-in |
|
800W75Ω |
800W75Ω |
1 |
|
11 kW |
Built-in |
|
1000W50Ω |
1000W50Ω |
1 |
|
15 kW |
Built-in |
|
1500W40Ω |
1500W40Ω |
1 |
|
18.5kW |
Built-in |
|
2500W35Ω |
2500W35Ω |
1 |
|
22 kW |
Built-in |
|
3000W27.2Ω |
1500W54Ω |
2 |
|
30 kW |
4030 |
1 |
5000W19.2Ω |
2500W40Ω |
2 |
|
37 kW |
4045 |
1 |
6000W16Ω |
2000W50Ω |
3 |
|
45 kW |
4045 |
1 |
9600W13.6Ω |
2500W54Ω |
4 |
|
55 kW |
4030 |
2 |
12000W10Ω |
2000W60Ω |
6 |
|
75 kW |
4045 |
2 |
19200W6.8Ω |
2000W60Ω |
8 |
|
|
|
|
|
Power Resistor Unit |
Qty(PCS) |
|
|
90 kW |
4030 |
3 |
9600W20Ω |
3 |
|
|
110 kW |
4220 |
1 |
9600W20Ω |
3 |
|
|
132-160kW |
4220 |
1 |
40KW3.4Ω |
1 |
|
|
185-220 kW |
4220 |
1 |
60KW3.2Ω |
1 |
|
|
250-315 kW |
4220 |
2 |
40KW4.5Ω |
2 |
|
|
315-600 kW |
4220 |
3 |
60KW3Ω |
3 |
Related Products
News Center
> What is a Frequency Inverter?
A frequency inverter is designed to manage the operation of electric motors by adjusting the frequency of the input power. By controlling the speed and torque of the...
> What is a Solar Pumping Inverter
A Solar Pumping Inverter is a device designed to convert the direct current (DC) electricity generated by solar panels into alternating current (AC) to power water p...
> How to operate the motor control panel?
As the core component of the motor control system, the correct operation of the motor control panel is crucial to ensure the stable operation of the motor, improve p...
> how does a soft start work?
It is a device used to control the starting process of an AC motor. Its main purpose is to limit the initial large current inrush of the motor at startup, thereby pr...